Static load testing is the method by which the load displacement characteristics of a pile can be determined. All piles are suited to testing in this way. In order to apply a known load to the test pile some form of reaction is necessary. The most commonly used methods are kentledge or tension pile reaction, dependent upon ground conditions. Other methodologies can be adopted according to site requirements e.g. in areas of restricted access or headroom. Once adequate reaction has been provided, the test is carried out using a hydraulic jack and calibrated digital load cell to a previously agreed procedure. Time, load, and displacement data are usually recorded.
AHAM currently provides supervision services as a 3rd party for such tests and issues confirmatory reports to the tests carried out on site.
|
|
|
|
|